Eyecon 9420

Home Solutions Eyecon 9420

Revolutionary Tabletop Automation: Prescription Validation, Counting and Filling System

The Eyecon™ 9420 is a unique machine vision counting system. A camera mounted above the counting platter captures photo images used to count pills five times per second. If a count is questioned, the photo can be viewed and/or printed. Every pill is sequentially numbered and all of the prescription data is annotated onto the photo.

The Eyecon 9420 uses a unique Visual Counting System™  that is up to 76% faster and significantly more accurate than manual counting. It helps reduce tedium and stress while allowing employees to spend more time with customers. Your customers will benefit from improved customer service and Rx accuracy.

Eyecon 9420 builds on the revolutionary technology of the original Eyecon machine, with enhanced features that take the system to the next level. The updated widescreen display presents more information in a single view and the touchscreen delivers enhanced brightness, touch accuracy and supports multi-touch for pinch and zoom. When the machine vision technology detects pill fragments or foreign matter on the counting platter, it alerts the operator. This feature ensures the quality of the prescriptions filled on the Eyecon.

For most pharmacies, Eyecon pays for itself very quickly. Filling automation improves Rx accuracy, resulting in improved customer safety, inventory control and customer satisfaction, saving an average pharmacy thousands of dollars per year.

The next generation Eyecon is READY. Are you…

Call us today at 877-797-2332
or fill out the form above.

We’ll guide you to pharmacy automation bliss!

Improves Rx Accuracy

Improves Rx Accuracy

Field-tested near 100% accuracy
More accurate than manual counting
Faster Prescription Filling

Faster Prescription Filling

Up to 76% faster than manual filling
Avoids Waste

Avoids Waste

Eliminates inventory shrinkage due to over-fills
Improves Customer Satisfaction

Improves Customer Satisfaction

Download Our Data Sheet and Dare to Compare!

DRI Enabled & CII Compliant

RxSafe’s Data Rich Interchange

Technology sets RxSafe apart.
One of our most recent developments is the DRI™, the first-of-its-kind, message initiation “data rich interchange” for the retail pharmacy market. This protocol is essential for real workflow, providing pharmacy management with a complete suite of reports at their fingertips. The DRI is an integral part of every RxSafe product, making it a unique offering in pharmacy management software. With the development of the DRI, pharmacy workflow becomes even more robust and streamlined than ever before.

Eyecon® optical precision counting system

The Eyecon® optical precision counting system captures a “shadow image” and numbers each pill counted for filling the prescription. The image is stored with the prescription number for reference. Pill “fragments” or foreign material is identified in the image prior to process completion for remedy.

Unbeatable Features & Specs

Eyecon™ 9420 Features

  • Eliminate over-dispensing and giving away pills
  • Fill prescriptions more quickly for reduced patient wait-time
  • Reduce customer frustration by avoiding under-fills
  • Ensure the correct drug is dispensed
  • Fewer partial-fills due to more accurate inventory
  • Reduce time spent on physical inventories
  • Reduce the number of nuisance claims of under-filled prescriptions for narcotics
  • Many false claimants cease attempts to obtain more pills once they are shown the annotated tray photo
  • Reduce legal liability through stock bottle validation and enhanced record-keeping
  • Save time and improve the accuracy of keeping track of partial fills
  • Produce reports for external auditors to document prescription filling activity
  • Be confident placing higher price and narcotic drugs into robotics by using Eyecon to double-count

Specifications for Eyecon™ 9420 System

Platter Surface Area 48″ sq.
Dimensions W=11” L=17.5” H=28”
Weight 18 lbs. (30 lb. ship weight)
Widescreen Display 7″ diagonal, 800 x 480 IPS LCD with LED backlighting
Integrated Barcode Scanner High performance 1D and 2D scan engine, motion tolerant and LED aiming dot
Warranty Two year limited
Approvals UL / cUL approval for USA and Canada, UL File Number E490213
US Patent # 8,682,047

Specifications for Eyecon™ 9420 Controller

PMS Compatibility Interfaces to over 20 pharmacy management software systems
Database Regular updates to drug database and user interface
Ports Two (2) USB 3.0 ports / Gigabit Ethernet port
Operating System Windows 10 Enterprise 2016 LTSB
Processor Intel® Core™ i3-5010U dual core
Storage 128 GB SSD
RAM 8GB
Power 100-240 VAC, 47-60Hz

Eyecon™ 9420 Field Performance Data

Pill Count Product Avg. Fill Time
30 pills Eyecon® 9420 13.6 sec
GSE Model 664 Scale 15.6 sec
Competitive Brand 17.1 sec
Hand Counting 26.9 sec
60 pills Eyecon® 9420 14.1 sec
GSE Model 664 Scale 16.9 sec
Competitive Brand 21.9 sec
Hand Counting 47.7 sec
90 pills Eyecon® 9420 15.9 sec
GSE Model 664 Scale 17.0 sec
Competitive Brand 26.8 sec
Hand Counting 66.6 sec
Menu